Click to enlarge image
|
Model Number |
OP 160 |
Features
Real-Time Smoke Measurement
- OP160 offers partial-flow, sampling-type diesel opacity measurement.
- Excellent Korean Technology certified from Korean government, Ministry of Science & Tech.
- It meets all requirements of international standard ISO11614.
- Snap-acceleration test
- Follow-up mode test
- Data recording
- Engine speed measurement
- Engine oil temperature measurement
- Optical and sampling unit
- Connecting wire
- Display unit
- Output display
- Power supply
- Measuring accuracy
- Rugged construction
Specifications
|
Light source
|
LED, 563nm(peak)
|
|
Light detector
|
Photodiode
|
| Output display |
Graphic LCD 0.1% resolution
|
|
Accuracy
|
Less than (0.5%)
|
|
Measuring range
|
0.0 ~ 100.0 % opacity
|
|
2nd order Bessel filter
|
0.45 sec response time
|
|
Measuring interval
|
0.01 sec
|
|
Zero drift
|
Less than 0.2% per hour
|
|
Warm-up time
|
10~20 sec
|
|
Analog output
|
0 ~ 1 or 0~5 Volt
|
|
Input power
|
100~220 VAC
|
|
|
|
|
| |
|
|
|